Resolution and response time of various corrosion monitoring techniques, reported for subsea oil and gas production equipment:

 

Technique Resolution Response Time at 1 mpy corrosion rate Response Time at 40 mpy corrosion rate
Electrochemical 1 µA minutes minutes
FSM™ (25 mm wall thickness) 0.025 mm 1 year days
Electrical Resistance (0.25 mm sensor) 0.00025 mm 4 days minutes
Ultrasonic Thickness Transducer (fixed) 0.1 mm 4 years 40 days
Weight Loss Coupon 1 mg months days

 

Reference:

M.W. Joosten, K.P. Fischer, R. Strommen, K.C. Lunden: "Internal Corrosion Monitoring of Subsea Oil and Gas Production Equipment",  Materials Performance, April 1995, pp.44-48.

 